What is the ideal HERMS coil length? Theory and experiments

Introduction

When we started selling HERMS coils 2 years ago, we made our 40cm coil 15 meters (50 feet) long. The 30cm coil was 11.5m long. Why? That’s what most home brewers were doing.

But we recently started to suspect that such a long coil is not optimal. Sure, a longer coil will give you a higher output temperature, but it will also have more friction, reducing your flow. Each extra loop of the coil will cause a small temperature rise, but with diminishing returns for each extra loop. But each extra loop will also add a additional amount of friction.
The amount of heat transferred to the mash tun depends on both the achieved input-to-output temperature difference and the flow rate, so there is a length that results in the maximum heat transfer. We set up an experiment to estimate what this length would be.

Below, you see a photo of the HLT we used for testing. It has a 40cm HERMS coil, made of stainless steel tubing (0.5mm wall thickness and 11mm inner diameter). The element is a 3500W element. Elco dry fired it once, which is why it turned black. It still works fine though. On the bottom right, you can see the temperature sensor and the dry fire protection which was installed after ruining the element.

TLDR

Based on our experiments, an 8 meter coil maximizes the heat transfer. This of course depends on many factors, like the coil material, your pump pressure and other losses in the system. We also found some other simple optimizations you can apply to your brewing setup and came up with a complete new coil design for big kettle setups.

HLT with BrewPi HERMS coil

Hot Liquor Tun setup with whirlpool, heating element and HERMS coil.

Heat transfer as function of flow and temperature difference

The amount of heat that is transferred every second (power in Watts) can be calculated by multiplying the volume that is transferred, the temperature difference between coil input and output and the specific heat capacity of water. In formula form:

\[ P = V \cdot \Delta T \cdot c_p\]

So to heat up your mash as quickly as possible, you want to maximize this equation.

Experiment setup

To find the ideal length, we needed to determine 2 things:

1. How much does each loop of the coil contribute to temperature rise?

It costs a lot of work and money to make multiple coils of different lengths, so we came up with an alternative: we decreased the amount of water in the HLT, submerging only a fraction of the coil. We assumed that only the submerged loops are contributing to the output temperature significantly.

Timelapse of HLT water levels

Hot Liquor Tun water levels for each successive test.

2. How much friction does each loop add?

This one is a bit harder to test, so we took a more theoretical approach. We measured the flow rate twice, once bypassing the entire coil and once pumping through the coil. From the difference in flow rate, we calculated the friction factor of the entire coil. We used that value to calculate the friction that shorter coils would have.

The experiments

Flow rate

We measured the flow simply by filling a bucket with the return tube of the HLT, timing it and weighing the amount of water. The results were:

  • 5.8 liters per minute with the coil
  • 9.8 liters per minute without the coil.

Switching between with and without coil could be done by simply toggling a valve. Because it is fully automated Elco’s system has a lot of tubing, meaning there will be a lot more friction. In simpler setups with less tubing you will get higher flow. We correct for that later.

Flow calculations

There’s a lot of math in this section, feel free to skip it. What we did is measure the flow with and without the coil and from the difference we calculated the friction of the coil.

v

To calculate  (flow velocity in meters per second) we used the Bernoulli formula.

Bernoulli formula:

\[(p_{1} + \frac{1}{2}\rho v_{1}^{2} + \rho g z_{1})-(p_{2} + \frac{1}{2}\rho v_{2}^{2} + \rho g z_{2})=f \frac{1}{2} \frac{L}{d} \rho v^{2} + K \frac{1}{2} \rho v^{2}\]

Without the coil, this formula simplifies to:

\[p_{pump}= K \frac{1}{2} \rho v^{2}\]

This allows us to calculate K, our dimensionless loss factor for everything except the coil.

\[K = \frac{2 \cdot p_{pump}}{\rho v^{2}}\]
\rho
\Big[ \frac{kg}{m^{3}} \Big]

Our pump pressure is known from manufacturer (4.5m head), and the density of water  at 60°C is 980 

f

Now that we have a good estimation for the loss factor K, the friction factor  of the the coil can be determined from the difference in flow velocity. The pressure of the pump does not change, so we can solve the following formula.

\[p_{pump} = f \frac{1}{2} \frac{L}{d} \rho v_{1}^{2} + K \frac{1}{2} \rho v_{1}^{2} = K \frac{1}{2} \rho v_{2}^{2}\]
\[f=K \cdot \frac{d}{L} \frac{v_{2}^{2}-v_{1}^{2}}{v_{1}^{2}}\]

Now that the friction factor of the coil is calculated it can be used to estimate the speed of the wort for different coil lengths.

\[v = \sqrt{\frac{2 \cdot p_{pump}}{\rho (f \frac{L}{d}+K)}}\]

We got a resulting friction factor of 0.0407, giving the following flow curves for a K of 30.

Pump flow and speed for Elco's system

Volume flow and velocity for Elco’s system for various coil lengths

Elco’s system has a lot of tubing and valves, because it is fully automated. You can see the schematic of the entire system here:

Elco’s brewery with automated valves, interactive demo

To mimic our experiment in this setup, select the mash recirculation step. By toggling valve v6 we could bypass the coil.

And here are some photos of the setup:

Temperature sensors on coil

With the temperature sensors inline with the coil, we could measure the coil in and output temperature.

Elco's setup water pump cluster

This cluster pumps water from the HLT or water input to the HLT (top valve v1) or router cluster (bottom valve v2)

Elco's setup wort pump cluster

This cluster gets water from the MT (top left v9) or BK (bottom left v10) and pumps it to the router cluster via the CFC (bottom right v12) and bypassing the CFC (top right v11) or drain (middle v13)

Elco's setup router cluster

This router cluster gets clean water from the left or wort from the right. The connections at the bottom are MT in (v3) coil out (v5) coil in (v7) or BK in (v8). By toggling v6, in between v5 and v7, we could bypass the HERMS coil.

This shows the water input on the right, with a valve for the water pump cluster and the CFC and a ‘to fermenter’ output on the left.

As you can see from the photos above, Elco’s setup has a lot of tubing and valves. This results in a lot of friction in the system, and therefore a high K factor. We think a K of 15 will be more representative of a typical homebrew setup.

A loss factor K of 15 will result in the following flow charts.

Pump flow curve using f value of 0.0407 and K value of 15

Volume flow and velocity for a more typical system with less tubing and valves

Coil efficiency vs. length

To measure the temperature distribution through the coil, we measured the output temperature of the coil for different water levels in the HLT. We measured:

  • 1.5 loops submerged
  • 3.5 loops submerged
  • 5.5 loops submerged
  • 7.5 loops submerged
  • 9.5 loops submerged
  • 11.5 loops submerged

For each water level in the HLT we recirculated the mash tun water through the HERMS coil to go from 55°C to 65°C, while trying to keep the HLT at 70 degrees. We measured:

  • Coil in temperature
  • Coil out temperature
  • Mash tun in temperature
  • Mash tun out temperature
  • HLT temperature

Here you can see the measurements form having 11.5 loops submerged:

brewpi data test 2 using 11.5 meter submerged coil

Raw data as recorded by the BrewPi brewing controller

For each measurement we started the HLT at 70 degrees and the MT at 55. We then closed valve v6 to switch from bypassing the coil to pumping through the coil.
After each run, we would discard some water from the MT, add some fresh cold water and make sure it was back at 55 degrees with the same volume for the next test.

\eta

We measured the input temperature difference (HLT – coil in) and the output temperature difference (coil out – coil in), so for each point in time we can calculate the efficiency  of the submerged section:

\[\eta = 1 - \frac{\Delta T_{out}}{\Delta T_{in}}= 1- \frac{coil_{out}-coil_{in}}{HLT - coil_{in}}\]

Each experiment would give us a set of points for the efficiency for a certain coil length. You can see these as a set of dots in the chart below. We only used the points for which the input temperature difference was between 4 and 8 degrees, which is the typical use case.

efficiency plot with temperature difference legend

Efficiency of a HERMS coil for different coil lengths

\eta = \eta_{max} \cdot (1 - e^\frac{-t}{\tau})
\tau
\eta_{max}
t

We fitted a curve through these points, with the formula  where  is a time constant based on the lumped thermal capacity model. Our fitted curve has a time constant of 4.5,  of 0.79, and  is the time spent in the submerged part of the coil, which can be calculated form the flow velocity.

t

Now we can use this formula to calculate the coil output temperature for different lengths by calculating the time spent in coil () first and entering it in this formula.

Heat transfer analysis based on our experiments

Now that we have determined how coil length changes flow rate and efficiency, we can use the formulas to calculate how much heat will be transferred for each coil length and temperature difference. As you can see in the chart below, the curves are as expected: making the coil longer increases the efficiency, but after a certain point the loss in flow rate cancels out the higher output temperature.

Power curve with respect to coil length

Power transferred to mash with different temperature differences between HLT and mash temperature

We have found 8.2 meters (dotted line) to be the most efficient length. The graph above is calculated with K = 15.

From the graph, you can also see that if your temperature difference is small, the power with which you heat your mash tun is low.

Recommendations for your own HERMS setup

During our experiments, we also found some quick improvements you can use to make your own mash go faster.

Exit the coil at the bottom

We did our experiments twice, once with the wort entering the coil at the top and leaving on the bottom and once the other way around. It turns out that having the wort in the HLT coil flow from top to bottom is more efficient that from bottom to top. This is because the water in the HLT is hotter closer to the element, even when there’s a whirlpool in the HLT. Our experiments found a 12% increase in efficiency when wort flowed from top to bottom.

coil efficiency comparison flow direction HERMS coil

Two efficiency curves with changing flow direction within HERMS coil

Keep the temperature difference high

V \cdot \Delta T \cdot C

Because the heat transferred per second is , to reach your mash temperature quickly, you will want to keep the temperature difference high. However, you don’t want to overshoot your target temperature. If you have a lot of water in the HLT, your HLT will continue to heat your mash if you keep pumping, even after you stop heating your HLT. All the heat that you put into your HLT will eventually distribute between your HLT and MT. A small example:

Let’s say you have 40L in your HLT and 40L in your mash tun. Your target temperature is 65 degrees and your mash is currently at 63 degrees. How high can you set your HLT to not overshoot? If you assume there are no temperature losses, the answer is 67 degrees. The equilibrium situation is that the HLT loses 2 degrees to the MT and both end up at 65:

\[ \frac{63 \cdot 40 + 67 \cdot 40}{40 + 40} = 65\]

Now let’s take another look with only 10L in the HLT, still 40L in the mash tun. Now you can heat up the HLT to 73:

\[ \frac{63 \cdot 40 + 73 \cdot 10}{40 + 10} = 65\]
\frac{\textrm{HLT volume}}{\textrm{mash volume}}

With a 4 times smaller HLT, you can heat your mash 4 times quicker without overshooting. If you use BrewPi for mashing, you would set your Kp for the PID that manages the HLT setpoint to the  to automatically manage the HLT setpoint.

So our recommendation is:

  • You can use a big kettle for your HLT, but don’t fill it up fully until you are heating your sparge water.
  • Mount your HLT coil as close to the bottom as possible
  • Use a low and wide HERMS coil if possible.

Whirlpool or stir your HLT

We measured the temperature response with and without recirculating our HLT water. This makes a big difference in the temperature exchange, as you can see from the graph below. Without stirring your HLT, the water around the coil will be a bit cooler, decreasing the output temperature.

Whirlpool vs no whirlpool in the HLT

Whirlpool vs. no whirlpool in the HLT

Our new HERMS coils

We changed the HERMS coils we sell based on these experiments.

Our 30cm HERMS coil has been shorted from 12 windings to 8 windings. It is now 7.5m long instead of 11.3m.

Our new 30cm HERMS coil

We are going to discontinue our 40cm HERMS coil, which was 15m long. The longer coil does not help with heat transfer. We have come up with an alternative though!
For big kettles, we have made a prototype of an entirely new design, suitable for big kettles and high power elements.

To maximize the heat transfer, we want to:

  • Maximize the time the wort is in the coil, to increase the efficiency
  • Reduce the friction of the coil

The only way to do both at once, is to increase the diameter of the coil. We chose to do this by having 3 coils in parallel, ending in one 1 inch fitting.

This design will have:

  • A lower velocity and therefore less friction, because the flow velocity per coil is lower and the coil is shorter
  • A lot of surface area
  • A very low height, making it possible to have only very little water in the HLT to be able to work with bigger temperature differences.

The 30 cm HERMS coils are back in stock now. For the new 3-way parallel super awesome high flow coil, we only made a few prototypes. They’ll be available in about 4 weeks.